Customization: | Available |
---|---|
Type: | Breathing Apparatus |
Inhalation Time: | 0~12 S. |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
s1100 Medical Oxygen Breathing Ventilator Machine
High Quality Breathing Machine;Oxygen Breathing Machine;Oxygen Breathing Ventilator
Application | The ventilator is suitable for various kinds of medical institutions for cardiopulmonary resuscitation respiratory support. Acute respiratory failure caused by various reasons or incomplete oxygenation dysfunction. Intra-operation, post-operation respiratory support, other respiratory treatment. |
|
Trust points | Simplicity: easy to use, easy to move with 4 wheels. |
|
Choice: adapt the equipment to your patients and procedures freely |
||
Patient Centered Ventilation: Precision in an anesthesia ventilator,fromconventional ventilation to advanced modes, including 8 modes: IPPV;A/C;PCV;SIMV; SPONT/CPAP;PSV;SIGH;MANU. |
||
Designed and manufactured by Darppon Medical with over 23 years experience in this area. |
||
International standard and advanced technology suitable for wide range use. |
||
Compact interface and big screen give you better operating experience. |
||
Over 2,000 units installed in the world. |
||
Features | 12.1" TFT LCD screen displays the Ventilation parameters, Alarming information and Waveform. |
|
Recycle breathing pipe, ensure easy operating and keep tidy. |
||
Multiple working modes such as volume control and pressure limit, adapt to wide range patient. |
||
Vaporizer with temperature, flow compensation and self-lock function, keep safety anytime. |
||
Multiple parameters monitoring interface, make every parameter clear, let users know the patient conditions in all aspects; |
||
Stable and low noise air compressor, create quiet work environment for doctors. |
||
Real time pressure-time, flow-time loop graphics and high precision O2 concentration detection function included. |
||
Safety | Three level alarming system, visual and sound alarm information. |
|
With lots of alarming, reminding and protection functions. |
||
Advanced power management control technology. |
||
With built-in backup power source, when outside power source goes off, back-up power source starts to work. |
||
Self-check before running, eliminate system mistake. |
||
Separate design of electric and gas, keep safety running of ventilator. |
||
Specifications | Ventilation modes: |
IPPV, A/C, PCV, SIMV, SPONT/CPAP, PSV,SIGH,MANU |
Ventilator parameter ranges |
||
Tidal volume(Vt) |
0 mL ~ 2000 mL | |
Frequence(Freq) |
1bpm ~ 100 bpm | |
I/E |
4:1~1:8 | |
PEEP |
0cmH2O ~ 40 cmH2O | |
Pressure triggering sensitivity(PTr) |
20 cmH2O ~ 100cmH2O | |
Flow trigger sensitivity (FTr) |
0.5 L/min ~ 30 L/min | |
Pressure Limit |
20 cmH2O ~ 100 cmH2O | |
Monitored Parameters |
||
Frequence(Freq) |
0 /min ~ 100 /min | |
Tidal volume(Vt) |
0 mL ~ 2500 mL | |
Oxygen concentration |
15 % ~ 100 % | |
Graphical display: |
Oxygen concentration | |
Size:Wooden case packing size:L560*W 560*H 605mm , GW:35KG ; NW:17KG |
||
L670*W700*H 1160 mm , GW:79KG ; NW:46.2KG |
||
Alarm and protection |
||
No tidal volume |
No tidal volume within 6s | |
High oxygen concentration alarm |
19%-100% | |
Low oxygen concentration alarm |
18%-99% | |
High Airway pressure alarm |
20cmH2O-100cmH2O | |
Low Airway pressure alarm |
0cmH2O-20cmH2O | |
High Minute Volume alarm |
5L/min-99L/min | |
Low Minute Volume alarm |
1L/min-30L/min | |
Continuous Pressure alarm |
(PEEP+1.5kPa) over 16s | |
Suffocation warning |
5s-60s | |
The maximum limited pressure |
<12.5 kPa | |
Fan error |
Show on screen | |
Oxygen deficit |
Show on screen | |
Working conditions |
||
Gas source |
O2,AIR | |
Pressure |
280kPa-600kPa | |
Voltage |
-220V±22V | |
Power frequency |
50Hz±1Hz | |
Input power | 900VA(with air compressor) | |
250VA(without air compressor) |