Type: Breathing Apparatus
G.W: 35kg
Ventilation  Mode: Ippv, Sippv, Simv, Manual
Power: AC 220V-10%  
Pressure Range  : 10~60 CMH2o
Customized: Non-Customized
Customization:
Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
DP-2000B1
Certification
CE, ISO13485
Scale
Large
Transport Package
Mood and Packaging
Specification
60*62*122
Trademark
DARPPON
Origin
China
HS Code
90189070
Production Capacity
30000

Product Description

DP-2000B1 medical apparatus vertical type  hospital ventilator apparatus in surgery

 

 

Technical parameters

DP-2000B1 is a multi-functional Ventilator, it is applicable for children and adults in sickroom, ICU or of emergency.
Ventilator
Display mode High-definition 5.7" LCD screen display
Ventilation  mode IPPV, SIPPV, SIMV, MANUAL
Ventilation functions PEEP,SIGH, IRV
Ventilation parameters Tidal volume 50~1500 ml
Rate 2~99bpm
SIMV rate 2~20 bpm
I:E 2:1~1:8
Pressure trigger sensitivity -10~20 cmH2O
PEEP                   0~20 cmH2O
Pressure range            10~60 cmH2O
SIGH  1.5 times the inspiratory 
time
Parameters for ventilation monitoring tidal volume, minute ventilation volume, IPPV rate,
 SIMV rate, total respiratory rate, I/E, peak pressure
 of airway, pressure - time waveform, flow rate - 
time waveform, PEEP, inspiratory trigger pressure
Security Alarm System
Airway pressure alarm upper limit setting range  10~60 cmH2O
low limit setting range     4~20 cmH2O
Per-minute ventilation volume alarm upper limit setting range   3~30L/min
low limit setting range   1~10L/min
Sustained high-pressure alarm it will give alarm when stress have consistently been
 higher than 25 cmH2O
Suffocation alarm it will give sound and light alarm if there is no tidal 
volume input for 15 seconds
Power alarm
Power AC 220V±10%     50Hz±1Hz(UPS, Storage battery)

Medical Apparatus Vertical Type Hospital Ventilator Apparatus in Surgery

Medical Apparatus Vertical Type Hospital Ventilator Apparatus in Surgery
Medical Apparatus Vertical Type Hospital Ventilator Apparatus in Surgery

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now